Franklin Tester

Image: Franklin Tester
 
 
Tester with electronic control   Automatic
measurement
 
 
Surface resistance
Resistance distribution
Coating thickness (optional)
Determination of surface resistance of individual samples of electrical steel and punched parts
Quality control of insulation coating
Manually operated or fully automatic version
Preparation and execution of the measuring process according to ASTM-standard A 717-81
and IEC 60404-11

Publication

 
 

"Franklin Tester enables easier quality control of coated electrical steel..."

read article
add to checklist
   

Operating principle

Measuring the total current which flows along the insulation coating of the sample when pressure is applied via several contacts. Conversion of the measured value to an equivalent surface resistance. Suitable especially for quality control of insulation coating.

Constructed from 2 main components:

• Voltage supply unit
• Testing device with hydraulic pump

The test head consists of two longitudinal rows of five vertically mounted steel rods which are free to move axially against the surrounding spiral springs. A stainless steel measuring contact is positioned at each end of each rod. It is possible to move the test head hydraulically perpendicular to a surface.

The testing contacts are pressed onto the insulation coating with a pressure of 129N per electrode. An electrical contact to the steel sheet is created with a spiral drill. If the resistance is finite a current proportional to the resistance flows through the insulation coating.

Operating method: Measuring the insulation via all 10 electrodes. Display of single resistance per electrode is also possible.

 Technical data: Franklin Tester
Testing voltage: 0.5 V, 0.1 mV resolution
Accuracy of settings: ± 0.5 %
System accuracy: ± 1 %
System resolution: 0.1 mV
Measuring unit for hydraulic pressure: 0 to 25 bar ± 5 % (1290 N ± 5 %)
Test head: electr. contact: 10 contact pins
total area: 6.45 cm² ± 1 %
Maximum testing pressure: 25 bar (displayed value)
Weight
(manually operated version):
voltage supply unit approx. 6kg
device and pump approx. 70 kg
Supply voltage: 230 V AC, 50 Hz
 